Technical Specifications of NSN
Body Style:
Multipole-single actuator type
Body Length:
5.000 inches
Center To Center Distance Between Terminals Parallel To Length:
3.625 inches
Center To Center Distance Between Terminals Parallel To Width:
1.688 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
4.250 inches
Switch Contact Arrangement:
Single pole, single throw, normally closed
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Boss Height:
0.312 inches
Mounting Surface To Terminal End Distance:
4.625 inches
Mounting Facility Type And Quantity:
2 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
20
Maximum Continuous Load Current Rating Per Pole:
200.0 amperes ac all locations and 200.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
125.0 ac all locations and 125.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
10000.0 ac all locations and 5000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal-magnetic all locations
Trip Release Characteristic:
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
138.0 all locations
Ultimate Trip Time Per Pole In Seconds:
3600.000 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
External Actuator Linkage Arrangement:
One, two, and three linked
Auxiliary Switch Function And Quantity:
1 alarm
Thread Size:
0.250 inches
Inclosure Protection Type For Which Designed:
Fungus resistant
Trip Release Ambient Tempurature Rating:
50.0 degrees celsius all locations
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
10.0 ac and 10.0 dc
Switch Voltage Rating And Type In Volts:
125.0 ac and 125.0 dc
Frequency In Hertz:
60.0 all locations
Test Data Document:
81349-mil-c-17588 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Specification Data:
81349-mil-c-17588 government specification
Item Name:
Tri-break Fused Circuit Breaker
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC